Following section describes the procedure for replacing a FRU requiring maintenance from the system.
The following FRUs can be maintained:
- CMU/IOU (CPU Memory Board Unit/IO Unit)
- FAN (Fan Unit)
- PSU (Power Supply Unit)
- XSCFU (Extended System Control Facility Unit)
- Log in to the XSCF shell.
- Execute the replacefru command to display the maintenance menu.
XSCF> replacefru |
- Select the FRU requiring maintenance by specifying it with a numeric key.
In the following example, since the fan unit is selected, “2” is entered.
—————————————————————————— Maintenance/Replacement Menu Please select a type of model which has FRU to be replaced. 1. CMU/IOU (CPU Memory Board Unit/IO Unit) 2. FAN (Fan Unit) 3. PSU (Power Supply Unit) 4. XSCFU (Extended System Control Facility Unit) —————————————————————————— Select [1,2|c:cancel] :2 |
- Select the FRU requiring maintenance by specifying it with a numeric key.
In the following example, since FAN#6 is showing “Faulted” indicating an error, “7” is entered.
—————————————————————————— Maintenance/Replacement Menu Please select a FRU to be replaced. No. FRU Status — ——————- ————– 1 /FAN#0 Normal 2 /FAN#1 Normal 3 /FAN#2 Normal 4 /FAN#3 Normal 5 /FAN#4 Normal 6 /FAN#5 Normal 7 /FAN#6 Faulted —————————————————————————— Select [1-7|b:back] :7 |
- After confirming that the selected FRU is displayed, enter [r].
You are about to replace FAN#6. Do you want to continue?[r:replace|c:cancel] : r |
- Confirm that the CHECK LED of the FRU is blinking.
Please execute the following steps: 1) Confirm the Check LED is blinking. 2) Remove FAN#6. 3) Execute either the following: 3-1) After installing the exchanged device, please select ‘finish’. 3-2) If you want to suspend the maintenance without exchanging device, please select ‘cancel’. [f:finish|c:cancel] : |
You can now start FRU maintenance. Do not enter “f” until you complete the maintenance work.
Another Example for replacing PSU:
XSCF> replacefru ---------------------------------------------------------------------- Maintenance/Replacement Menu Please select a type of FRU to be replaced. 1. CMU/IOU (CPU Memory Board Unit/IO Unit) 2. FAN (Fan Unit) 3. PSU (Power Supply Unit) 4. XSCFU (Extended System Control Facility Unit) ---------------------------------------------------------------------- Select [1-4|c:cancel] :3 ---------------------------------------------------------------------- Maintenance/Replacement Menu Please select a PSU to be replaced. No. FRU Status --- --------------- ------------------ 1. PSU#0 Normal 2. PSU#1 Normal 3. PSU#2 Normal 4. PSU#3 Normal 5. PSU#4 Normal 6. PSU#5 Normal 7. PSU#6 Normal 8. PSU#7 Normal 9. PSU#8 Normal 10. PSU#9 Normal 11. PSU#10 Normal 12. PSU#11 Normal 13. PSU#12 Normal 14. PSU#13 Normal 15. PSU#14 Normal 16. PSU#20 Normal 17. PSU#21 Normal 18. PSU#22 Normal 19. PSU#23 Normal 20. PSU#24 Normal 21. PSU#25 Normal 22. PSU#26 Faulted 23. PSU#27 Normal 24. PSU#28 Normal 25. PSU#29 Normal 26. PSU#30 Normal 27. PSU#31 Normal 28. PSU#32 Normal 29. PSU#33 Normal 30. PSU#34 Normal 31. PSU#40 Normal 32. PSU#41 Normal 33. PSU#42 Normal 34. PSU#43 Normal 35. PSU#44 Normal 36. PSU#45 Normal 37. PSU#46 Normal 38. PSU#47 Normal 39. PSU#48 Normal 40. PSU#49 Normal 41. PSU#50 Normal 42. PSU#51 Normal 43. PSU#52 Normal 44. PSU#53 Normal 45. PSU#54 Normal 46. PSU#60 Normal 47. PSU#61 Normal 48. PSU#62 Normal 49. PSU#63 Normal 50. PSU#64 Normal 51. PSU#65 Normal 52. PSU#66 Normal 53. PSU#67 Normal 54. PSU#68 Normal 55. PSU#69 Normal 56. PSU#70 Normal 57. PSU#71 Normal 58. PSU#72 Normal 59. PSU#73 Normal 60. PSU#74 Normal ---------------------------------------------------------------------- Select [1-60|b:back] :22 You are about to replace PSU#26. Do you want to continue?[r:replace|c:cancel] :r Please confirm the Power LED is blinking or not lit. If this is the case, please replace PSU#26. After replacement has been completed, please select[f:finish] :f Diagnostic tests for PSU#26 have started. [This operation may take up to 30 second(s)] (progress scale reported in seconds) 0.done ---------------------------------------------------------------------- Maintenance/Replacement Menu Status of the replaced FRU. FRU Status ------------- -------- PSU#26 Normal ---------------------------------------------------------------------- The replacement of PSU#26 has completed normally.[f:finish] :f ---------------------------------------------------------------------- Maintenance/Replacement Menu Please select a type of FRU to be replaced. 1. CMU/IOU (CPU Memory Board Unit/IO Unit) 2. FAN (Fan Unit) 3. PSU (Power Supply Unit) 4. XSCFU (Extended System Control Facility Unit) ---------------------------------------------------------------------- Select [1-4|c:cancel] :c